List of some of the larger UK Power Plant live outputs (down to individual plant/turbine/generator level) categorised by “Fuel Type”.
KNOWN ISSUES: See “Known Issues Tab”
Updates every 1/2 Hour. To be added to as an ongoing exercise. See here to view in graphical format.
Grid Overview
Wind (Offshore)
Plant ID: T_HOWAO-1
1/2 Hr TP: 48
Installed Equip: 174x Siemens Wind Power (7 MW)*
Max Output: 1,218MW*
Output: 0.000 MW
Plant ID: T_HOWAO-2
1/2 Hr TP: 48
Installed Equip: 174x Siemens Wind Power (7 MW)*
Max Output: 1,218MW*
Output: 400.000 MW
Plant ID: T_HOWAO-3
1/2 Hr TP: 48
Installed Equip: 174x Siemens Wind Power (7 MW)*
Max Output: 1,218MW*
Output: 395.000 MW
Plant ID: T_RMPNO-1
1/2 Hr TP: 48
Installed Equip: 116x Vestas V112 (3.45MW)*
Max Output: 400MW*
Output: 150.000 MW
Plant ID: T_RMPNO-2
1/2 Hr TP: 48
Installed Equip: 116x Vestas V112 (3.45MW)*
Max Output: 400MW*
Output: 143.000 MW
Plant ID: T_BEATO-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 30.000 MW
Plant ID: T_BEATO-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 34.000 MW
Plant ID: T_BEATO-3
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 48.000 MW
Plant ID: T_BEATO-4
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 50.000 MW
Plant ID: T_GANW-11
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 83.000 MW
Plant ID: T_GANW-13
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 83.000 MW
Plant ID: T_GANW-22
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 83.000 MW
Plant ID: T_GANW-24
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 84.000 MW
Plant ID: T_GRGBW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 150.000 MW
Plant ID: T_GRGBW-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 156.000 MW
Plant ID: T_GRGBW-3
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 155.000 MW
Plant ID: T_THNTO-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 114.000 MW
Plant ID: T_THNTO-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 114.000 MW
Plant ID: T_EAAO-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 0.000 MW
Plant ID: T_EAAO-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 340.000 MW
Plant ID: T_LARYW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 134.000 MW
Plant ID: T_LARYW-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 139.000 MW
Plant ID: T_LARYW-3
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 130.000 MW
Plant ID: T_LARYW-4
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 131.000 MW
Plant ID: T_RCBKO-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 239.000 MW
Plant ID: T_RCBKO-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 239.000 MW
Plant ID: T_WLNYW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 73.000 MW
Plant ID: T_WLNYO-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 119.000 MW
Plant ID: T_WLNYO-3
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 237.000 MW
Plant ID: T_WLNYO-4
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 203.000 MW
Plant ID: T_GYMR-15
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 65.000 MW
Plant ID: T_GYMR-17
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 1.000 MW
Plant ID: T_GYMR-26
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 23.000 MW
Plant ID: T_GYMR-28
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 17.000 MW
Plant ID: T_WDNSO-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 43.000 MW
Plant ID: T_WDNSO-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 43.000 MW
Plant ID: T_BRBEO-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 258 MW
Output: 78.000 MW
Plant ID: T_MOWEO-1
1/2 Hr TP: 48
Installed Equip: 100x Vestas V164 (9.5MW)*
Max Output: 950MW*
Output: 57.000 MW
Plant ID: T_MOWEO-2
1/2 Hr TP: 48
Installed Equip: 100x Vestas V164 (9.5MW)*
Max Output: 950MW*
Output: 64.000 MW
Plant ID: T_MOWEO-3
1/2 Hr TP: 48
Installed Equip: 100x Vestas V164 (9.5MW)*
Max Output: 950MW*
Output: 56.000 MW
Plant ID: T_TKNWW-1
1/2 Hr TP: 48
Installed Equip: 90x Vestas V164 (9.5MW)*
Max Output: 855MW*
Output: 364.000 MW
Plant ID: T_TKNEW-1
1/2 Hr TP: 48
Installed Equip: 90x Vestas V164 (9.5MW)*
Max Output: 855MW*
Output: 361.000 MW
Plant ID: T_WTMSO-1
1/2 Hr TP: 48
Installed Equip: *
Max Output:
Output: 173.000 MW
Plant ID: T_HMGTO-1
1/2 Hr TP: 48
Installed Equip:
Max Output:
Output: 68.000 MW
Plant ID: T_HMGTO-2
1/2 Hr TP: 48
Installed Equip:
Max Output:
Output: 72.000 MW
Plant ID: T_LNCSW-1
1/2 Hr TP: 48
Installed Equip:
Max Output:
Output: 124.000 MW
Plant ID: T_LNCSW-2
1/2 Hr TP: 48
Installed Equip: *
Max Output:
Output: 132.000 MW
Plant ID: T_GNFSW-1
1/2 Hr TP: 48
Installed Equip:
Max Output:
Output: 80.000 MW
Plant ID: T_GNFSW-2
1/2 Hr TP: 48
Installed Equip:
Max Output:
Output: 51.000 MW
Plant ID: T_RREW-1
1/2 Hr TP: 48
Installed Equip:
Max Output:
Output: 20.000 MW
Plant ID: T_DDGNO-1
1/2 Hr TP: 48
Installed Equip: *
Max Output:
Output: 90.000 MW
Plant ID: T_DDGNO-2
1/2 Hr TP: 48
Installed Equip:
Max Output:
Output: 77.000 MW
Plant ID: T_DDGNO-3
1/2 Hr TP: 48
Installed Equip:
Max Output:
Output: 99.000 MW
Plant ID: T_DDGNO-4
1/2 Hr TP: 48
Installed Equip:
Max Output:
Output: 98.000 MW
Sites Under Construction / Testing (i.e data may not be genuine)
*Denotes total windfarm capacity across all metering points, not split over individual meters as shown (1.1, 1.2…)
Wind (Onshore)
Plant ID: T_WHILW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 17.000 MW
Plant ID: T_WHILW-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 4.000 MW
Plant ID: T_KILBW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 17.000 MW
Plant ID: T_FALGW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 1.000 MW
Plant ID: T_CLDNW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 2.000 MW
Plant ID: T_CLDCW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 2.000 MW
Plant ID: T_CLDSW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 1.000 MW
Plant ID: T_BLLA-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 124MW
Output: 0.000 MW
Plant ID: T_BLLA-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: 63MW
Output: 1.000 MW
Plant ID: T_HRSTW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 136MW
Output: 1.000 MW
Plant ID: T_KLGLW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 239MW
Output: 64.000 MW
Plant ID: T_BHLAW-1
1/2 Hr TP: 48
Installed Equip: *
Max Output:
Output: 3.000 MW
Interconnectors
Plant ID: INTFR
1/2 Hr TP: 45
Installed Equip: HV-DC Link
Max Output: +/- 2,000 MW
Output: 1504 MW
Plant ID: INTIRL
1/2 Hr TP: 45
Installed Equip: HV-DC Link
Max Output: +/- 500 MW
Output: -452 MW
Plant ID: INTNED
1/2 Hr TP: 45
Installed Equip: HV-DC Link
Max Output: +/- 1,000 MW
Output: 1004 MW
Plant ID: INTEW
1/2 Hr TP: 45
Installed Equip: HV-DC Link
Max Output: +/- 500 MW
Output: -528 MW
Plant ID: INTNEM
1/2 Hr TP: 45
Installed Equip: HV-DC Link
Max Output: +/- 1,000 MW
Output: -182 MW
Plant ID: INTELEC
1/2 Hr TP: 45
Installed Equip: HV-DC Link
Max Output: +/- 1,000 MW (2022)
Output: 996 MW
Plant ID: INTIFA2
1/2 Hr TP: 45
Installed Equip: HV-DC Link
Max Output: +/- 1,000 MW
Output: 992 MW
Plant ID: INTNSL
1/2 Hr TP: 45
Installed Equip: HV-DC Link
Max Output: +/- 1,400 MW (Oct 2021)
Output: 1400 MW
Solar
Nuclear
Plant ID: T_TORN-1
1/2 Hr TP: 48
Installed Equip: AGR
Max Output: 682 MW
Output: 0.000 MW
Plant ID: T_TORN-2
1/2 Hr TP: 48
Installed Equip: AGR
Max Output: 682 MW
Output: 648.000 MW
Plant ID: T_SIZB-1
1/2 Hr TP: 48
Installed Equip: PWR
Max Output: 599 MW
Output: 599.000 MW
Plant ID: T_SIZB-2
1/2 Hr TP: 48
Installed Equip: PWR
Max Output: 595 MW
Output: 595.000 MW
404 Not Found – Check API-URL!
We have a Problem with JSON here:
Either we got no JSON from the API. Or the basenode-parameter is not ok.
Switch on the Debugmode of the Plugin!
404 Not Found – Check API-URL!
We have a Problem with JSON here:
Either we got no JSON from the API. Or the basenode-parameter is not ok.
Switch on the Debugmode of the Plugin!
Plant ID: T_HINB-7
1/2 Hr TP: 48
Installed Equip: AGR
Max Output: 655 MW
Output: 0.000 MW
Plant ID: T_HINB-8
1/2 Hr TP: 48
Installed Equip: AGR
Max Output: 655 MW
Output: 0.000 MW
Plant ID: T_HEYM11
1/2 Hr TP: 48
Installed Equip: AGR
Max Output: 575 MW
Output: 497.000 MW
Plant ID: T_HEYM12
1/2 Hr TP: 48
Installed Equip: AGR
Max Output: 575 MW
Output: 555.000 MW
Plant ID: T_HEYM27
1/2 Hr TP: 48
Installed Equip: AGR
Max Output: 625 MW
Output: 0.000 MW
Plant ID: T_HEYM28
1/2 Hr TP: 48
Installed Equip: AGR
Max Output: 625 MW
Output: 644.000 MW
Plant ID: T_HRTL-1
1/2 Hr TP: 48
Installed Equip: AGR
Max Output: 595 MW
Output: 567.000 MW
Plant ID: T_HRTL-2
1/2 Hr TP: 48
Installed Equip: AGR
Max Output: 595 MW
Output: 585.000 MW
Gas
Plant ID: T_CARR-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 0.000 MW
Plant ID: T_CARR-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: *
Output: 0.000 MW
Plant ID: T_CDCL-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 450 MW
Output: 0.000 MW
Plant ID: T_DAMC-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 812 MW
Output: 0.000 MW
Plant ID: T_HUMR-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 1,230 MW
Output: 349.000 MW
Plant ID: T_GRAI-6
1/2 Hr TP: 48
Installed Equip: *
Max Output: 425 MW
Output: 0.000 MW
Plant ID: T_GRAI-7
1/2 Hr TP: 48
Installed Equip: *
Max Output: 425 MW
Output: 0.000 MW
Plant ID: T_GRAI-8
1/2 Hr TP: 48
Installed Equip: *
Max Output: 425 MW
Output: 0.000 MW
Plant ID: T_LAGA-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 885 MW
Output: 0.000 MW
Plant ID: T_ROCK-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 800 MW
Output: 0.000 MW
Plant ID: T_PEMB-11
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: T_PEMB-21
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: T_PEMB-31
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: T_PEMB-41
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: T_PEMB-51
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: T_RYHPS-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 715 MW
Output: 0.000 MW
Plant ID: T_SCCL-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 400 MW
Output: 0.000 MW
Plant ID: T_SCCL-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: 400 MW
Output: 340.000 MW
Plant ID: T_SCCL-3
1/2 Hr TP: 48
Installed Equip: *
Max Output: 400 MW
Output: 0.000 MW
Plant ID: T_MRWD-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 898 MW
Output: 0.000 MW
Plant ID: T_SEAB-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 755 MW
Output: 748.000 MW
Plant ID: T_SEAB-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: 385 MW
Output: 0.000 MW
Plant ID: T_SHBA-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 820 MW
Output: 0.000 MW
Plant ID: T_SHBA-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: 580 MW
Output: 0.000 MW
Plant ID: T_SPLN-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 880 MW
Output: 0.000 MW
Plant ID: T_STAY-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: T_STAY-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: T_STAY-3
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: T_STAY-4
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: E_FAWN-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 150 MW
Output: 80.000 MW
Plant ID: E_GYAR-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 398 MW
Output: 0.000 MW
Plant ID: E_KLYN-A-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 382 MW
Output: 0.000 MW
Plant ID: E_SHOS-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 420 MW
Output: 0.000 MW
Plant ID: T_KEAD-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 367 MW
Output: 0.000 MW
Plant ID: T_KEAD-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: 367 MW
Output: 0.000 MW
Plant ID: T_LBAR-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 698 MW
Output: 0.000 MW
Plant ID: T_WBURB-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: T_WBURB-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: T_WBURB-3
1/2 Hr TP: 48
Installed Equip: *
Max Output: 430 MW
Output: 0.000 MW
Plant ID: T_CNQPS-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 375 MW
Output: 0.000 MW
Plant ID: T_CNQPS-2
1/2 Hr TP: 48
Installed Equip: *
Max Output: 375 MW
Output: 0.000 MW
Plant ID: T_CNQPS-3
1/2 Hr TP: 48
Installed Equip: *
Max Output: 375 MW
Output: 0.000 MW
Plant ID: T_CNQPS-4
1/2 Hr TP: 48
Installed Equip: *
Max Output: 375 MW
Output: 0.000 MW
Plant ID: T_DIDCB5
1/2 Hr TP: 48
Installed Equip: *
Max Output: 720 MW
Output: 0.000 MW
Plant ID: T_DIDCB6
1/2 Hr TP: 48
Installed Equip: *
Max Output: 720 MW
Output: 0.000 MW
Plant ID: T_PEHE-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 1,200 MW
Output: 0.000 MW
Plant ID: E_PETEM1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 360 MW
Output: 0.000 MW
Plant ID: T_EECL-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 410 MW
Output: 0.000 MW
Plant ID: E_CORB-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: 350 MW
Output: 0.000 MW
Plant ID: T_COSO-1
1/2 Hr TP: 48
Installed Equip: *
Max Output: MW
Output: 0.000 MW
Grid Storage (Battery)
Plant ID: E_BHOLB-1
1/2 Hr TP: 48
Installed Equip: Tesla 7.5MW
Max Output: 7.5MW?
Output: 0.000 MW
Plant ID: T_WBURB-41
1/2 Hr TP: 48
Installed Equip: ?
Max Output: ? MW
Output: 0.000 MW
Plant ID: T_WBURB-43
1/2 Hr TP: 48
Installed Equip: ?
Max Output: ? MW
Output: 0.000 MW
Plant ID: E_ARNKB-1
1/2 Hr TP: 48
Installed Equip: ?
Max Output: 41 MW
Output: 0.000 MW
Plant ID: T_PNYCB-1
1/2 Hr TP: 48
Installed Equip: ?
Max Output: 22 MW
Output: 0.000 MW
Plant ID: E_CRSSB-1
1/2 Hr TP: 48
Installed Equip: ?
Max Output: 20MW
Output: 0.000 MW
Plant ID: E_ROOSB-1
1/2 Hr TP: 48
Installed Equip: ?
Max Output: 49 MW
Output: 0.000 MW
Plant ID: T_COWB-1
1/2 Hr TP: 48
Installed Equip: ?
Max Output: 50 MW
Output: 0.000 MW
Plant ID: T_KEMB-1
1/2 Hr TP: 48
Installed Equip: ?
Max Output: 50 MW
Output: 0.000 MW
Plant ID: E_CONTB-1
1/2 Hr TP: 48
Installed Equip: Tesla 68MWh
Max Output: 38 MW
Output: 0.000 MW
Grid Storage (Pumped)
Plant ID: T_DINO-1
1/2 Hr TP: 48
Installed Equip – Hydro: Reversible Francis
Max Output: 300 MW
Output: 0.000 MW
Plant ID: T_DINO-2
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 300 MW
Output: 0.000 MW
Plant ID: T_DINO-3
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 300 MW
Output: 0.000 MW
Plant ID: T_DINO-4
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 300 MW
Output: 0.000 MW
Plant ID: T_DINO-5
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 300 MW
Output: 0.000 MW
Plant ID: T_DINO-6
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 300 MW
Output: 0.000 MW
Plant ID: T_FFES-1
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 90 MW
Output: 0.000 MW
Plant ID: T_FFES-2
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 90 MW
Output: 0.000 MW
Plant ID: T_FFES-3
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 90 MW
Output: 0.000 MW
Plant ID: T_FFES-4
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 90 MW
Output: 0.000 MW
Plant ID: T_CRUA-1
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 120 MW
Output: -128.000 MW
Plant ID: T_CRUA-2
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 120 MW
Output: -128.000 MW
Plant ID: T_CRUA-3
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 100 MW
Output: 0.000 MW
Plant ID: T_CRUA-4
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 100 MW
Output: 0.000 MW
Plant ID: M_SLOY-1
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 40 MW
Output: 0.000 MW
Plant ID: T_SLOY-2
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 40 MW
Output: 0.000 MW
Plant ID: T_SLOY-3
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 40 MW
Output: 0.000 MW
Plant ID: M_SLOY-4
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 32.5 MW
Output: 0.000 MW
Plant ID: T_FOYE-1
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 150 MW
Output: 0.000 MW
Plant ID: T_FOYE-2
1/2 Hr TP: 48
Installed Equip: Hydro – Reversible Francis
Max Output: 150 MW
Output: 0.000 MW
Virtual Power Plants (VPP)
Plant ID: V__LFLEX001
1/2 Hr TP: 48
Installed Equip: ?
Max Output: ? MW
Output: 0.000 MW
Plant ID: V__NFLEX001
1/2 Hr TP: 48
Installed Equip: ?
Max Output: ? MW
Output: 0.000 MW
Plant ID: V__PFLEX001
1/2 Hr TP: 48
Installed Equip: ?
Max Output: ? MW
Output: 0.000 MW
Biomass
Plant ID: T_DRAXX-1
1/2 Hr TP: 48
Installed Equip: 1x CA Parsons Turbogen.
Max Output: 660MW
Output: 0.000 MW
Plant ID: T_DRAXX-2
1/2 Hr TP: 48
Installed Equip: 1x CA Parsons Turbogen.
Max Output: 660MW
Output: 340.000 MW
Plant ID: T_DRAXX-3
1/2 Hr TP: 48
Installed Equip: 1x CA Parsons Turbogen.
Max Output: 660MW
Output: 0.000 MW
Plant ID: T_DRAXX-4
1/2 Hr TP: 48
Installed Equip: 1x CA Parsons Turbogen.
Max Output: 660MW
Output: 645.000 MW
Plant ID: E_LYNE1
1/2 Hr TP: 48
Installed Equip: 1x Parsons Turbogen
Max Output: 140MW
Output: 126.000 MW
Plant ID: E_LYNE2
1/2 Hr TP: 48
Installed Equip: 1x Parsons Turbogen
Max Output: 140MW
Output: 121.000 MW
Plant ID: E_LYNE3
1/2 Hr TP: 48
Installed Equip: 1x Parsons Turbogen
Max Output: 140MW
Output: 0.000 MW
Plant ID: T_JGPR-1
1/2 Hr TP: 48
Installed Equip:
Max Output: 12MW
Output: 5.000 MW
Plant ID: E_MARK-1
1/2 Hr TP: 48
Installed Equip:
Max Output: 55 MW
Output: 0.000 MW
Plant ID: T_TSREP-1
1/2 Hr TP: 48
Installed Equip:
Max Output: 299MW
Output: 0.000 MW
Plant ID: T_WILCT-1
1/2 Hr TP: 48
Installed Equip:
Max Output: 30MW
Output: 0.000 MW
Plant ID: E_TGP1
1/2 Hr TP: 48
Installed Equip:
Max Output:
Output: 42.000 MW
In process of being converted:
Plant ID: T_USKM-13
1/2 Hr TP: 24
Installed Equip:
Max Output: 110 MW
Output: 0.000 MW
Plant ID: T_USKM-14
1/2 Hr TP: 24
Installed Equip:
Max Output: 110 MW
Output: 0.000 MW
Plant ID: T_USKM-15
1/2 Hr TP: 24
Installed Equip:
Max Output: 110 MW
Output: 0.000 MW
Coal
Plant ID: T_WBUPS-1
1/2 Hr TP: 48
Installed Equip: 1x English Electric Turbogen
Max Output: 500MW
Output: 0.000 MW
Plant ID: T_WBUPS-2
1/2 Hr TP: 48
Installed Equip: 1x English Electric Turbogen
Max Output: 500MW
Output: 0.000 MW
Plant ID: T_WBUPS-3
1/2 Hr TP: 48
Installed Equip: 1x English Electric Turbogen
Max Output: 500MW
Output: 0.000 MW
Plant ID: T_WBUPS-4
1/2 Hr TP: 48
Installed Equip: 1x English Electric Turbogen
Max Output: 500MW
Output: 0.000 MW
Plant ID: T_RATS-1
1/2 Hr TP: 48
Installed Equip: 1x Parsons Generator
Max Output: 500MW
Output: 0.000 MW
Plant ID: T_RATS-2
1/2 Hr TP: 48
Installed Equip: 1x Parsons Generator
Max Output: 500MW
Output: 0.000 MW
Plant ID: T_RATS-3
1/2 Hr TP: 48
Installed Equip: 1x Parsons Generator
Max Output: 500MW
Output: 0.000 MW
Plant ID: T_RATS-4
1/2 Hr TP: 48
Installed Equip: 1x Parsons Generator
Max Output: 500MW
Output: 0.000 MW
Plant ID: T_DRAXX-5
1/2 Hr TP: 48
Installed Equip: 1x CA Parsons Turbogen.
Max Output: 660MW
Output: 0.000 MW
Plant ID: T_DRAXX-6
1/2 Hr TP: 48
Installed Equip: 1x CA Parsons Turbogen.
Max Output: 660MW
Output: 0.000 MW
OCGT / Blackstart
Plant ID: T_WBUGT-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: T_WBUGT-4
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: T_LBAR-1G
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: T_KEADGT-3
1/2 Hr TP: 48
Installed Equip:
Max Output: 25 MW
Output: 0.000 MW
Plant ID: T_DRAXX-9G
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: T_DRAXX-10G
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: T_DRAXX-12G
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: T_RATSGT-2
1/2 Hr TP: 48
Installed Equip:
Max Output: 17.5MW
Output: 0.000 MW
Plant ID: T_RATSGT-4
1/2 Hr TP: 48
Installed Equip:
Max Output: 17.5 MW
Output: 0.000 MW
Plant ID: T_SEEL-1
1/2 Hr TP: 48
Installed Equip:
Max Output: 300 MW
Output: 0.000 MW
Plant ID: T_INDQ-1
1/2 Hr TP: 48
Installed Equip:
Max Output: 140 MW
Output: 0.000 MW
Plant ID: E_FDUN-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_RDFRD-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_RDFRB-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_DBFRM-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_BSPHM-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_MORFL-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_ALCOA-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_CHTRY-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_GOSHS-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_LCHWT-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_LSTWY-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_MDLWH-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_RAKE-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_RDSCR-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_SUDME-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_TDRVE-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_TRFPK-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_WTRLN-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_BURGH-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Plant ID: E_CHICK-1
1/2 Hr TP: 48
Installed Equip:
Max Output: MW
Output: 0.000 MW
Known Issues:
1: API data lag from BMRS: “latest physical data (Near Real Time) is for current 1/2-hour settlement period + 2” -basically everything you see here is an hour out of date. If you are comparing the Grid Overview vs an individual plant and it doesn’t add up this is normally why. (I’m working on a way around this)
2: FPN vs MEL Figures: Currently all output figures above are “Physical Notifications” (FPN) from the plant. These are usually accurate HOWEVER there are occasions (such as when gradually raising load on a nuclear plant or uncertainty on wind from an offshore windfarm) that a Plant Specific “Maximum Export Limit (MEL)” may be set lower than the FPN. As such, the true output in this case is more likely to be nearer the lower MEL figure.
Ultimately, I need to figure a way of choosing the lower of the two values from the data (if FPN > MEL then Plant Output = MEL…) but this is again work in progress.
4: Solar – As far as I can find, no solar farms appear in BMRS data. If you know of any please let me know.
5: Interconnectors are a different data stream. I have it, just not implemented yet. Done 11/8/2021
6: All of this is Beta so don’t take it a 100% accurate or use it for anything critical. I’ve not spent any time tracking this data over time to make sure it’s all perfect yet. (And I’ve a lot of plant turbine/genset info to trawl through.)